Automated tracking mechanism for optimal energy yield
少儿英语培训
Why Source Direct from Our 45,000m² Factory in China?
98.7% On-Time Delivery
25 + million $
Total Investment
45000 +
Factory Area SQM
65 +
Production Lines
340 +
Skilled Workers
25000 TON+
Monthly capacity
1261 +
Solar Projects
907 +
Steelstructural projects
32 +
Cooperated Countrys
CE (EN 1090), UL 2703/6703, TÜV, IEC 62446 certified. Documentation packages tailored for EU, US, MENA, APAC markets. Pre-approved structural calculations accelerate project permitting.
Full control from raw steel coil → hot-dip galvanizing (65μm+) → Zn-Al-Mg coating → precision fabrication. Eliminates third-party quality risks. Every component traceable with mill test reports and coating certificates.
PV Mounting System Technical Compendium - Global Engineering Parameters Manual
| Items | Specification/Description | Applicable Standards |
|---|---|---|
| SYSTEM TYPES & APPLICATIONS | ||
| Ground-Mount Structural Systems | Single-pile/multi-row arrays; Ground clearance 300-1800mm adjustable; Max span 8.0m; PHC pile 300AB 70-4.5 | IEC 61215, ASCE 7-16, GB50794-2012, EN 1993 |
| Rooftop Mounting Systems | Ballasted flat roof (5°-15° tilt); Metal roof L-foot brackets (0°-15° slope); No roof penetration; Pre-assembled modules | UL 2703, Eurocode 1/3/8/9, Dubai Municipality Standards |
| Solar Carport Systems | Two-car coverage; Max span 5.4m; Waterproof design; Steel consumption: 160-210 tons/MW | FM 4474, UL 2703, Eurocode 1/3, IBC 2018 |
| Agrivoltaic Livestock Systems | Sheep/Cattle shelter integrated PV; Column height 3760mm; V/D-type water channels; No roof penetration | ISO 13789, IEC 61701, EN 1991-1-3, FAO Guidelines |
| MATERIAL SPECIFICATIONS | ||
| Structural Steel | Q235B/Q355B; Yield strength ≥235/355MPa; Tensile strength ≥370/470MPa | GB/T 700, EN10025-2:2004, ASTM A36 |
| Cold-Formed Sections | U41x52x2.0/U41x41x2.0; Thickness tolerance ±0.15mm; Straightness ≤2mm/m | GB/T 6725, GB/T 6728, EN 10219 |
| Hot-Dip Galvanized Steel | Zinc coating ≥65μm (structural); ≥55μm (fasteners); Sulfate copper test: 5 cycles | GB/T 13912, ISO 1461, ASTM A123 |
| Zn-Al-Mg Coated Steel (Magnelis®) | ZM310 coating 275g/m²; Zn 94%/Al 3%/Mg 3%; Self-healing cut-edge protection | JIS H 8641, ISO 9223 C5-M, ASTM B117 (2000h) |
| Aluminum Alloy | 6063-T5/T6; Tensile strength ≥160/205MPa; Anodized finish 15-18μm silver matte | GB/T 5237, EN 755, ASTM B221 |
| Stainless Steel Fasteners | A2-70 (304)/A4-80 (316); Corrosion resistance C3-C4 environments; Tensile strength ≥700/800MPa | ISO 3506, ASTM A276, EN 10088 |
| STRUCTURAL PARAMETERS | ||
| Wind Load Capacity | Static load 4.5kN/m²; Dynamic load 300km/h (3-sec gust); Exposure category C | IEC 61400-22, ASCE 7-16, EN 1991-1-4 |
| Snow Load Capacity | Uniform load 3.5kN/m²; Ground snow load 1.7kN/m²; Shape coefficient μ=0.8-2.0 | EN 1991-1-3, GB50009-2012, Jordanian Building Code |
| Seismic Resistance | Horizontal acceleration 0.35-0.4g; Site class D; Base isolation design | IBC 2018, GB50011-2010, Japan Building Code |
| Geometric Dimensions | Rail length: 2.4m/3.2m (std), up to 12m (custom); Max span: 5.4m (carport), 8.0m (ground) | UL 2703, EN 1090, GB 50205 |
| ENVIRONMENTAL ADAPTABILITY | ||
| Coastal/Marine Environments | Magnelis® ZM310 coating; 20-year perforation warranty; Cut-edge self-healing protection | ISO 9223 C5-M, IEC 60721-3-6, ASTM B117 |
| Desert/High-Temp Regions | Dust-proof design; Operating temp -20°C to +85°C; Sand accumulation resistant | IEC 60068-2-68, IEC 61701, SASO 2859:2018 |
| Cold Climate Regions | Low-temp impact steel S355J2; Automatic snow removal; Anti-freeze fastener coating | EN 10025-3, EN 1993-1-10, ASTM A370 |
| ELECTRICAL & SAFETY REQUIREMENTS | ||
| Grounding System | Continuity resistance <0.1Ω; Earth resistance <10Ω; 25mm² copper conductor min | UL 467, IEC 60364-4-41, NEC Article 690 |
| Lightning Protection | Type I+II SPD; Discharge current 12.5kA (10/350μs); Response time <25ns | IEC 62305, UL 1449, NFPA 780 |
| IP Rating | After installation: IP65; Junction box: IP68; Dust tight, water jet protected | IEC 60529, UL 6703, NEMA 250 |
| GLOBAL CERTIFICATIONS BY REGION | ||
| European Market | CE marking under CPR; TÜV structural certification; DoP documentation | EN 1090, Eurocodes 1/3/8/9, Construction Products Regulation |
| North American Market | UL listed components; NEC 2020 compliant; Wind uplift tested | UL 2703, UL 6703, NEC Article 690, IBC 2018 |
| Middle East Market | SASO certified; High-temp testing 85°C/1000h; Local Saudization compliance | SASO 2859:2018, Dubai Municipality Standards, NEOM Project Standards |
| Asia-Pacific Market | Anti-typhoon design 180km/h; Salt fog 2000h; Humid heat adaptation | TIS 2545 (Thailand), SNI 8259 (Indonesia), MS IEC 61215 (Malaysia) |
| QUALITY WARRANTY | ||
| Structural Components | Main structure: 25 years design life; Connectors: 15 years; Corrosion protection: 12-20 years | GB50068-2018, ISO 12447, ASTM G101 |
| Corrosion Protection Warranty | C2 (rural/urban): 25y; C3 (industrial/marine): 15y; C4 (severe): 10y; C5 (extreme): 8y | ISO 9223, ISO 12944, ASTM B117 |
Vertical integration advantage
Through consolidated procurement with 20+ major steel mills.
According to the statistics:
We shorten the delivery time average 7 days at least.
we achieve 5-8% material cost savings transferred to your order
20*40GP Containers: 15 Days Production Cycle
Shorten delivery time by 35% → 35000 ㎡ intelligent workshop
Cost reduction of 18% → 22000 tons/month Efficiency production
Certification Assurance
Can be rigorously tested by internationally recognized bodies including:
CE Certified Solar Mounting Solutions – Powering Europe with Compliance
BV (Bureau Veritas) for material traceability
SGS for welding procedure qualification (ISO 15614-1)
✓ Digitally verifiable test certificates
✓ Full compliance documentation pack
✓ Optional 3rd-party reinspection at your designated agency